Handover: Sample run
Ask each centrifugal compressor manufacturer to state the gas, inlet temperature and inlet pressure used for the quoted volumetric flow, then to keep measured package power on that same row. A sample that only shows a family-range endpoint from a public table (for example a published NX 1800-style pairing of kW/hp, barg/psig and m³/min/cfm) is a unit reminder, not this project’s performance. The sample run should also name control at minimum plant demand so a later SAT is not arguing about blow-off air that was never priced.
Site readiness
Factories should confirm cooling-water supply temperature and quality, three-phase voltage/phase/frequency, compressed air for instruments, skid footprint, rotor-pull space, and the PLC or local-panel interface. If the plant cannot provide those utilities on the requested delivery window, the quote is not executable even when the compressor list is complete. Site readiness is a buyer input this service helps list; it is not a construction contract we perform.